Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BackgroundNasal high flow (nHF) therapy provides heated, humidified air and oxygen via two small nasal prongs, at gas flows of more than 1 litre/minute (L/min), typically 2 L/min to 8 L/min. nHF is commonly used for non-invasive respiratory support in preterm neonates. It may be used in this population for primary respiratory support (avoiding, or prior to the use of mechanical ventilation via an endotracheal tube) for prophylaxis or treatment of respiratory distress syndrome (RDS). This is an update of a review first published in 2011 and updated in 2016.ObjectivesTo evaluate the benefits and harms of nHF for primary respiratory support in preterm infants compared to other forms of non-invasive respiratory support.Search methodsWe used standard, extensive Cochrane search methods. The latest search date March 2022.Selection criteriaWe included randomised or quasi-randomised trials comparing nHF with other forms of non-invasive respiratory support for preterm infants born less than 37 weeks' gestation with respiratory distress soon after birth.Data collection and analysisWe used standard Cochrane Neonatal methods. Our primary outcomes were 1. death (before hospital discharge) or bronchopulmonary dysplasia (BPD), 2. death (before hospital discharge), 3. BPD, 4. treatment failure within 72 hours of trial entry and 5. mechanical ventilation via an endotracheal tube within 72 hours of trial entry. Our secondary outcomes were 6. respiratory support, 7. complications and 8. neurosensory outcomes. We used GRADE to assess the certainty of evidence.Main resultsWe included 13 studies (2540 infants) in this updated review. There are nine studies awaiting classification and 13 ongoing studies. The included studies differed in the comparator treatment (continuous positive airway pressure (CPAP) or nasal intermittent positive pressure ventilation (NIPPV)), the devices for delivering nHF and the gas flows used. Some studies allowed the use of 'rescue' CPAP in the event of nHF treatment failure, prior to any mechanical ventilation, and some allowed surfactant administration via the INSURE (INtubation, SURfactant, Extubation) technique without this being deemed treatment failure. The studies included very few extremely preterm infants less than 28 weeks' gestation. Several studies had unclear or high risk of bias in one or more domains. Nasal high flow compared with continuous positive airway pressure for primary respiratory support in preterm infants Eleven studies compared nHF with CPAP for primary respiratory support in preterm infants. When compared with CPAP, nHF may result in little to no difference in the combined outcome of death or BPD (risk ratio (RR) 1.09, 95% confidence interval (CI) 0.74 to 1.60; risk difference (RD) 0, 95% CI -0.02 to 0.02; 7 studies, 1830 infants; low-certainty evidence). Compared with CPAP, nHF may result in little to no difference in the risk of death (RR 0.78, 95% CI 0.44 to 1.39; 9 studies, 2009 infants; low-certainty evidence), or BPD (RR 1.14, 95% CI 0.74 to 1.76; 8 studies, 1917 infants; low-certainty evidence). nHF likely results in an increase in treatment failure within 72 hours of trial entry (RR 1.70, 95% CI 1.41 to 2.06; RD 0.09, 95% CI 0.06 to 0.12; number needed to treat for an additional harmful outcome (NNTH) 11, 95% CI 8 to 17; 9 studies, 2042 infants; moderate-certainty evidence). However, nHF likely does not increase the rate of mechanical ventilation (RR 1.04, 95% CI 0.82 to 1.31; 9 studies, 2042 infants; moderate-certainty evidence). nHF likely results in a reduction in pneumothorax (RR 0.66, 95% CI 0.40 to 1.08; 10 studies, 2094 infants; moderate-certainty evidence) and nasal trauma (RR 0.49, 95% CI 0.36 to 0.68; RD -0.06, 95% CI -0.09 to -0.04; 7 studies, 1595 infants; moderate-certainty evidence). Nasal high flow compared with nasal intermittent positive pressure ventilation for primary respiratory support in preterm infants Four studies compared nHF with NIPPV for primary respiratory support in preterm infants. When compared with NIPPV, nHF may result in little to no difference in the combined outcome of death or BPD, but the evidence is very uncertain (RR 0.64, 95% CI 0.30 to 1.37; RD -0.05, 95% CI -0.14 to 0.04; 2 studies, 182 infants; very low-certainty evidence). nHF may result in little to no difference in the risk of death (RR 0.78, 95% CI 0.36 to 1.69; RD -0.02, 95% CI -0.10 to 0.05; 3 studies, 254 infants; low-certainty evidence). nHF likely results in little to no difference in the incidence of treatment failure within 72 hours of trial entry compared with NIPPV (RR 1.27, 95% CI 0.90 to 1.79; 4 studies, 343 infants; moderate-certainty evidence), or mechanical ventilation within 72 hours of trial entry (RR 0.91, 95% CI 0.62 to 1.33; 4 studies, 343 infants; moderate-certainty evidence). nHF likely results in a reduction in nasal trauma, compared with NIPPV (RR 0.21, 95% CI 0.09 to 0.47; RD -0.17, 95% CI -0.24 to -0.10; 3 studies, 272 infants; moderate-certainty evidence). nHF likely results in little to no difference in the rate of pneumothorax (RR 0.78, 95% CI 0.40 to 1.53; 4 studies, 344 infants; moderate-certainty evidence). Nasal high flow compared with ambient oxygen We found no studies examining this comparison. Nasal high flow compared with low flow nasal cannulae We found no studies examining this comparison.Authors' conclusionsThe use of nHF for primary respiratory support in preterm infants of 28 weeks' gestation or greater may result in little to no difference in death or BPD, compared with CPAP or NIPPV. nHF likely results in an increase in treatment failure within 72 hours of trial entry compared with CPAP; however, it likely does not increase the rate of mechanical ventilation. Compared with CPAP, nHF use likely results in less nasal trauma and likely a reduction in pneumothorax. As few extremely preterm infants less than 28 weeks' gestation were enrolled in the included trials, evidence is lacking for the use of nHF for primary respiratory support in this population.

Original publication

DOI

10.1002/14651858.cd006405.pub4

Type

Other

Publication Date

05/2023

Volume

5

Pages

CD006405 - CD006405

Addresses

Women's Newborn Research Centre, The Royal Women's Hospital, Parkville, Australia.

Keywords

Bronchopulmonary Dysplasia, Humans, Infant, Extremely Premature, Infant, Newborn, Oxygen, Pneumothorax, Respiration, Artificial, Surface-Active Agents