We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Background: Desaturation episodes occur commonly in ventilated preterm infants. It is not clear how best to reduce the frequency and duration of desaturation. Objective: To study the management of desaturation episodes using two bedside algorithms. Methods: Using a randomised crossover design, over two 8-hour periods, episodes were managed with either titration of inspired oxygen (FiO2) alone or adjustment to ventilator pressures with smaller changes to FiO2. Functional oxygen saturation and heart rate were downloaded from the bedside monitor. Ventilator parameters were captured simultaneously. The primary outcome was the proportion of time in the target saturation band. A cumulative measure of desaturation and oversaturation was also developed to compare groups. Results: 33 studies were performed in 23 ventilated infants <32 weeks’ gestation. Infants spent 51% of the time with saturations in the target band. There were more changes in ventilator pressure when the second algorithm was in use. There was no difference in the proportion of time within the saturation target, in the frequency and duration of desaturation episodes, or in the desaturation/oversaturation index between the two algorithms. Conclusions: Further study is required to determine the best way to manage desaturation in ventilated preterm infants.

More information Original publication

DOI

10.1159/000179611

Type

Journal article

Publisher

S. Karger AG

Publication Date

2009-01-01T00:00:00+00:00

Volume

95

Pages

306 - 310

Total pages

4